Industry Applications
Industry Applications

Preheating time of ballast with preheat soft-start function

Preheating time of ballast with preheat soft-start function Standard preheating duration: 0.5s ~ 2.0s

  • Common model: 1.0s (most widely used in UV industry)

  • Long life optimized model: 1.5~2.0s, fully heat the filament to reduce starting impulse

  • Short preheating model: 0.3~0.5s, applied for frequent on-off, less protection effect.

Working principle: During preheating period, ballast supplies low current to heat the filaments at both ends of lamp without high voltage ignition. After preheating, high voltage is applied to light up the UV lamp.


CONTACT US NOW
Hebei Guanyu Environmental Protection Equipment Co., Ltd. is a large-scale high-tech enterprise established in 2006, integrating technology development, equipment research and development, design, construction, and import and export trade.