Industry Applications
Industry Applications

Common Faults of Electronic Ballasts

  • Failure to start the lamp / lamp not lighting
    Poor connection, damaged internal components, faulty starting circuit, mismatched ballast and lamp.
  • Lamp flickering and unstable brightness
    Voltage fluctuation, abnormal drive circuit, aging capacitors and unstable power output.
  • Overheating and high housing temperature
    Poor heat dissipation, long-term full-load operation, high ambient temperature and overload.
  • Abnormal noise and hum
    Abnormal high-frequency oscillation, loose parts, magnetic core aging and installation resonance.
  • Frequent protection, automatic shutdown and restart
    Overcurrent, overvoltage, overheating, aging lamp leakage and short circuit.
  • Power attenuation and reduced UV intensity
    Aging of internal capacitors and power tubes leads to decreased output power.
  • Moisture corrosion and circuit board damage
    High humidity and corrosive gas cause circuit oxidation and electric leakage.
  • Burnout and breakdown (permanent damage)
    Power surge, short circuit and wrong wiring cause component breakdown and burning.